  1. All samples for the process variable "%" have at most one observation. Individual/Moving Range charts may be more appropriate.
  2.  
  3. Required parameters (like shift and target mean) have not been specified for some of the process variables.
  4.  
  5. Beta should be a positive probability value less than 1.0.
  6.  
  7. H or K must be positive.
  8.  
  9. Data units option used, constant sample size must be specified. 
  10.  
  11. Shift to be detected has not been specified.
  12.  
  13. There are not enough valid data to estimate standard deviation for the variable %.
  14.  
  15. For one-sided scheme, H must be specified for the cusum mask.
  16.  
  17. One of the following must be specified for the cusum mask : H, Alpha, or K Sigma.
  18.  
  19. A weight (between 0 and 1) for the average must be specified for the Exponentially Weighted Moving Average chart.
  20.  
  21. A span for computing the moving average should be specified for the Uniformly Weighted Moving Average chart.
  22.  
  23. Sample size variable must be numeric.
  24.  
  25. From Limits Table ‚Äò%0‚Äô, sample size value = %1, however, the dialog specifies the sample size value to be %2. 
  26.  
  27. K Sigma should be greater than 1. The most common value used is 3.
  28.  
  29. Cannot compute control limits for varying subgroup sample sizes since process standard deviation was not provided in the limits data table.
  30.  
  31. Select the data table which has the control limits for the different process variables.
  32.  
  33. For IR charts, range span should be an integer between 2 and 25.
  34.  
  35. For n=%
  36.  
  37. Note : Limits are based on alpha=%. 
  38.  
  39. Note : Limits are based on % sigma. 
  40.  
  41. Subgroup Sizes:
  42.  
  43. Possible precision problem.
  44.  
  45. Possible precision problem, lower probability limit set to 0.
  46.  
  47. Problem in evaluating probability function.
  48.  
  49. Unable to compute probability limits.
  50.  
  51. Center line cannot be less than the lower control limit(LCL) nor greater than the upper control limit(UCL).
  52.  
  53. There are samples with sample size less than 2. S Chart for "%" will not be created.
  54.  
  55. There are samples with sample size greater than 25 or less than 2. R Chart for "%" will not be created.
  56.  
  57. There are samples with sample size less than 2. S Chart will not be created.
  58.  
  59. There are samples with sample size greater than 25 or less than 2. R Chart will not be created.
  60.  
  61. Charts for "%" will not be created.
  62.  
  63. There are not enough data to estimate statistics.
  64.  
  65. All sample data are either 0 or missing.
  66.  
  67. Standard Deviation can not be negative.
  68.  
  69. For P Chart, data should either all be proportions or counts, but not both. 
  70.  
  71. Sample size should be positive.
  72.  
  73. Neither a valid sample size nor a sample size variable has been specified.
  74.  
  75. Not a single Limits table keyword was found in the specified table.
  76.  
  77. Lower control limit (LCL) can not be greater than the upper control limit(UCL).
  78.  
  79. Alpha should be a positive probability value less than 1.0.
  80.  
  81. Sample size should be a positive integer greater than 1.
  82.  
  83. Not a single column in the Limits data table has the same name as the specified process variables.  
  84.  
  85. Please set the label column for Control Chart's Limits data table. The label column should contain the keywords for the different parameters.  
  86.  
  87.